10 3. Description of electrical components 3.1. Motherboard
11 B1 - Lithium battery holder. We recommend replacement when the voltage is lower than 2.5 V, or at least once every three years. We recommend
12 Note: J18 – the connector is intended for connecting the PBX with a PC. It thus allows the programming of the PBX using the program OMEGA Lite
13 3.2. Power supply As the Power supply a power supply module with open construction and with output voltage of +24VDC/2.7A (connector J2)
14 The lever switch located on the right side of the chassis serves for switching the power on and off. The mains part is protected against
15 3.4. Display The LCD display is fitted on an independent holder and connected by means of a flat cable to the motherboard. It display
16 Other separate components 4. Extender module (order No 1880010) The extender module is intended for mounting in the basic PBX modul
17 5. Interface modules Order No Name of module Internal designation 2N Total number 1880030 Module 2x internal line OL2VL 12 1880038 Module 2x s
18 5.1. Module 2x internal line (order No 1880030) The internal line interface works with a line voltage of 24V and line current of approximately
19 5.2. Module 2x system telephone (order No 1880039) This is a four-wire interface, which must be respected for designing circuits ar
The 2N TELEKOMUNIKACE a.s. joint-stock company is a Czech manufacturer and supplier of telecommunications equipment. The product fami
20 Notes: In no case may system telephones be connected in parallel. LEDs (D1,D2) on the module signal by flashing ongoing communic
21 5.3. Module 2x system telephone – digital (order No. 1880038) Module for the connection of two digital system telephones 2N StarPoin
22 5.4. Module 1x external line / 1x internal line (order No 1880031) Combined module for connecting one analogue external (J2) and one analogue
23 5.5. Module 1x external line/1xinternal line with 16/12 kHz tariff pulse receivers (order No1880033/1880032) This module is completel
24 5.6. Module GSM 900/1800/1900 Mhz pro 1-2 GSM Order No 1880041 – for 1 GSM connection MC55i Order No 1880042 – for 2 GSM conn
25 The GSM module makes it possible to: automatically make calls to the GSM network and thus significant reduction in telephone bill of you
26 J5 - connector for USB interface to VoIP module (connector J3). J6 - service connector D1 - signalling LED D2 - signalling LED 5.8. Module
27 J1 - connector for connecting to motherboard (or extender module) (connector is secured against incorrect connection by the blanking of
28 5.9. Audio lines module (order No 1880019) The audio module is intended for voice services of the PBX such as VoiceMail, automatic operator, a
29 J1 - connector for connecting to motherboard (or extender module) (connector is secured against incorrect connection by the blanking
3 Dear customer, Congratulations on the purchase of the product 2N Omega Lite. This new product was developed and manufactured with an emphasis
30 Lite to - after connecting, earthed IN rest: has no reason connected: has no reason 4 binary input without power from OMEGA Lite, floating NO
31 Connection number 2 Connection number 3 Connection number 4
32 Connection number 5 Connection number 6 5.11. Module VoIP (Order No 1880021) The VoIP Module is designed exclusively for 2N® Omega Lite
33 Use the USB cable and the hyper-terminal for the initial setting of the IP address and the network mask; use the (available)
34 Detailed installation 6.1. Selection of place for PBX Aspects which must be taken into consideration when selecting a place for the PBX: G
35 module from the upper part. Open it and check everything against the packing sheet, which is a separate annex to the documentation. Chec
36 6.5. Installation of module UMTS/3G It is recommended to lift module into the motherboard (regarding to the length of connection cable). Interco
37 6.6. Installation of VoIP module Remove the display holder by unscrewing 2 screws on the chassis. Remove by turning the end cap on the
39 Remove 2 JUMPERs, J8/J9, from the main board. Unscrew 2 M3 screws from the left and right corner of the main board (these will be used
4 CONTENT 1. Basic module ...
40
41
42 Insert the two connectors attached into the J26 and J15 connectors on the main board.
43 Place the VoIP module onto the connectors inserted and fix it with two screws. Place the module onto the connectors ca
44
45
46 Connect the USB cable inserted (into J2 connector) and connect it with your PC. When connecting for the first time it is necessary to install
47 Serves for network parameter setup (IP address/network mask,.). After the network parameters have been set up you may disconnect. Always
48 7. Mounting PBX on wall Using the drilling template (on scale 1:1), mark two holes on the wall (for requirements for location see
49 disconnectable) from the nearest power socket (and check that it is correctly connected). Attach the wire to the chassis on the earth
5 10. Installation of front-end protection ... 51 11. Content of
50 8. Minor servicing tasks 8.1. Replacement of lithium battery The battery must be replaced if its voltage drops below 2.5 V. But
51 9. Expanding PBX The PBX can be expanded as desired by buying further modules up to the maximum configuration (24 lines). But
52 11. Content of expansion set 2N® Omega 48 expansion set contains: - Plastic cover - Mechanics of expansion deck - Data cable - Power cabl
53 7. Fasten down the expansion deck mechanics to chassis by two M3 screws (attached in the set). 8. Interconnect both mechanic pa
54 12. Technical parameters Nominal mains voltage 230 V Tolerance of mains voltage +/- 10 % Nominal frequency 50 Hz Input max. 90 VA Fuse F4A/25
55 External line parameters Analogue input impendence 600 +/- 20 % / ETSI Number of connected wires 2 Type of connector RJ-45 (PIN 4,5) 16 k
56 DTMF dialling receive parameters Receiver sensitivity -27 dB DTMF dialling send parameters: Frequencies According to Q23 Send level of lower
57 Nominal transmission attenuation: Internal connection 0 …8 dB External connection -0.5….+1.5 dB Interface RS232-C basic (galv. separate): Sign
58 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Tel.: +420 261 301 500, Fax: +420
6 1. Basic module Types of basic modules 1880000 - basic module without modem for RemoteSupervision up to 24 lines 1880001 - basic modul
7 In its assembled state, each basic module contains these parts: chassis (metal part of mechanism) with power source display plastic cove
8 Description of parts of basic module 2. Description of mechanical parts 2.1. Base (chassis) The base carries the other parts. The power su
9 2.2. PBX cover The plastic cover bears a sticker with a transparent window for the display. The cover is fitted on the chassis by fitting into