2N® Omega Lite Configuration Program User Manual Version 1.10.0 www.2n.cz
10 The standard password setting for both users is 1111. Without the password the PBX cannot be programmed. Please remember the password!
100 -after clicking Open, the abbreviated dialling is imported. 2.14.4. Errors during Abbreviated dialling Import If a file with abbrevi
101 -in the file, in column "Text" is used more than 16 chars, which is the max. possible value. - in the file, in column &qu
102 2.15. REMOTE SUPERVISION 2.15.1. What Remote Supervision Provides: instantaneous response to client needs 2N OMEGA Lite PBX programm
103 3. you must fill in the PBX Serial number. 4. you must fill in a phone number, which will be used for the remote modem connection. 5. you
104 Note: Always create access codes matching an existing valid serial number of gateway.
105 2.15.4. Description of OMEGA Lite Program Menus and Bar Buttons MENU – WINDOWS Panel – when the connection with the PBX to be supervised has
106 Connect to PBX the window with a directory tree for selecting a file to establish connection with the PBX to be supervised. Di
107 2.15.5. Types of Establishing Connection It is possible to establish connection with an 2N OMEGA Lite PBX to be supervised:
108 Establishing Connection 9. Run the OMEGA Lite Program SW. 10. set the
109 16. Now the connection is being established. 17. If everything is OK, the following information will be displayed gradually: establishing
11 2.1. Global data 2.1.1. Information This item informs you on the construction of the PBX that you are programming. Here you will find the num
110 2.15.7. MANUAL CONNECTION Setting of PBX To Be Supervised Manual connection is used if : 1. No automatic connection can be made. Exampl
111 remote supervision password confirmed. 10. The following data are displayed on the bottom bar from the left to the right: connection type
112 If you used manual connection, you will be invited to dial the telephone number manually. 2.15.12. Cancelling Connection To canc
113 The manufacturer reserves the right, in contrast to the submitted documentation, to make modifications to the product that will improve
114 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Tel.: +420 261 301 500, Fax: +420 261 301 599 E-mail: [email protected] Web
12 ME valid - licence expiring period of Mobility Extension service. ME count - maximum count of Mobility Extension service users. (default users c
13 2.1.2. Hardware Information on the physical construction of the PBX including the attachment of the individual types of modules at all positio
14 If you use external and internal lines with call identification support, then fill in the part Localisation: International fill in the int
15 FLASH length to CO. Enter the length of the FLASH signal generated by the PBX to the external port. Dial pulse to CO.
16 Don’t disintegrate conference. Allowing no collapse for conferencing between an internal line and at least two external lines after the inter
17
18 2.1.5. Internal lines Pulse #. The digit replacing the tone hash on pulse telephones. Pulse *. The digit replacing the tone asterisk on p
19
The 2N TELEKOMUNIKACE a.s. joint-stock company is a Czech manufacturer and supplier of telecommunications equipment. The product family devel
20 2.1.6. Tone parameters DTMF Increasing of DTMF resistant for DISA. Min. length of the DTMF sign that is accepted in the DISA di
21 -2nd Frequency = Amplitude to 31 -3rd Frequency = Amplitude to 21 Generator 1 (sine 1) -Default frequency 425 Hz. Generator 2 (sine 2) -
22
23 2.1.9. Emergency numbers A table listing the emergency numbers that the lines can call without authorisation. 15 numbers are availab
24 2.1.13. Tones and ringing In this screen you can change the type of tones and ringing in individual states. The screen is prima
25 Dialling tone Special held calls Baby call activate the Baby call/dispatcher regime Network dial tone simulated tone
26 2.1.14. Voices Here you can change the voice settings (system, user and music to make waiting more pleasant). System voices The
27 Mess The name of the voice as it is herein presented in the PBX configuration tool (e.g. as a DISA parameter in the ringing table). File The n
28 Permission for Modem switch for telemonitoring in the DISA detection is (according to the ringing table) selected (if it is sited) dir
29 2.1.17. AUDIO Groups The AUDIO inputs/outputs include eight AUDIO groups to be assigned to the Broadcast/Tape recorder service in the Groups/
3 Dear customer, Our compliments on buying the 2N OMEGA Lite. This new product was developed with an emphasis on the maximum possible use value
30 2.1.19. SMS Event reporting Here you can set PBX status monitoring through dispatching text messages, or SMS Event reporting. A text me
31 Enter: Number enter the number to which the SMS shall be sent. Port select a GSM port or bundle from which the dispatchingSMS sh
32 ISDN STATE send an SMS to notify an ISDN error and, subsequently, line clearing. CO STATE send an SMS to notify an external (analogue
33 A system or user voice message is the parameter. AUX external input (J25 connector on the main board). A voice message from an attach
34 2.2. Internal lines 2.2.1. Numbering This item offers a list of internal subscribers to the PBX. Here the individual ports are assigned a s
35 This table is for allocating a selection of bundles for external lines to internal lines (analogue and system) subscribers. If an int
36 2.2.2.2. Authorisations This table sets the authorisations for calling to a public telephone network in particular each internal lin
37 simulated dialling tone is given and the number called is checked to see if it is not the same as a code in the Dialling Analysis table. If a nu
38 2.2.2.3. Mask for dialling analysis This serves to set up one to four levels of saving for individual internal lines after the service Dial
39 The permission to receive CLIP on an analogue telephone is carried out in the marker activation. - CLIP function by sett
4 CONTENTS 1. The PBX configuration instrument menu ... 7 1.1. Data ...
40 -Call forwarding xxx - select one of the administrator forwarding settings (always, busy, no answer for Day/Night modes). For call forwar
41 2.2.4. Departments These tables are used during the Call Department service. In all there are 8 tables with 56 fields available. 2.
42 be modified for detecting a break in the connection using a disruption in the current loop. If the box Pulse dialling is not ticked then it only
43 2.3. System lines 2.3.1. Buttons In this MENU it is possible to set the programmable buttons for all of the connectable types
44 - Service (services e.g. switching from DAY/NIGHT, logging in to a department, allowing Mobility Extension,..) This is the procedure to
45 - Manager setting, a specific setting for the programmable buttons if at least one extender is connected. - Operator setting, a specific setting
46 2.3.1.1. OMEGA FCI Up to 20 programmable buttons can be set.
47 2.3.1.2. OMEGA LH Can also be set with extenders (16 buttons = telephone + 2x20 button Extender), up to 56 programmable buttons.
48 2.3.1.3. 2N StarPoint 500 It can also be set with the connected extenders (19 buttons = Advance telephone type + 1x90 button Extender), up
49 Set: - Key loudness, allows an acoustic signal when pressing system telephone buttons. - Earphone volume, volume control for the e
5 2.5. External lines ...
50 -Back call, the type of ringtone from a line that was blocked by the person being . - Special ca
51 2.3.2. Description of the buttons All of the descriptions of the buttons can be formed and then printed out in the environment
52 .
53 2.3.3. Allowing services This is where the permission for certain services on the pertinent system phones is done. - Can pick up remot
54 2.4.2. Direct selection on the bundles allowed The same set up and intent as with physical lines. 2.4.3. Tariff credit The same set up and
55 2.5. External lines 2.5.1. Types of lines In this table the properties of the individual lines for the analogue external lines is set up A
56 2.5.2. Types of digital lines S0 line Name - a maximum 14-character name for the external line DDI – ISDN line in the PTP connectio
57 Block Out – only an incoming external line and it cannot be entered on in the outgoing direction Auto TEI Without authorisation – check
58 GSM line Name - a maximum 14-character name for the external line Series – only an incoming external line which is not tested for cor
59 CLIR selection a choice of sending identification by operator - hide number - show number Prefix- a 4-digit
6 2.15.7. MANUAL CONNECTION ... 110 2.15.8. Downl
60 GSM linka-UMTS This setting is for voice parametres GSM-UMTS module to use it for common calling. If you want to use also UMTS DATA (inter
61 Data connection – enabling of the function Connection provider name – Informative name, e.g. provider name Dial number (optional) – d
62 You can check successfull conne case of successfull connection you can see there IP of the
63 VoIP Name – line name of max. 14 characters Without autoris. – the authorisation check will not be performed on this line Priva
64 2.5.3. GSM Services Set the GSM ports for which the GSM CLIP function is to be enabled. CLIP In enter the expected incoming GSM ident
65 2.5.4. Trunks The table serves for allocating individual external lines to a bundle. The maximum number of external lines in
66 Here you can select where the DISA is entered in the ringing table, so that after an incoming ringing on an external line it takes into account
67 2.5.7. Ringing table One of the following actions can be programmed in each row: Action Parameter Description Ring VL VL number or SYS Ringi
68 or until the incoming ringing from an external line DISA Number of voice from 1 to 10 = 0 Or nothing Stops previous ringing to internal lines an
69 Here are some working examples for illustration. Action Parameter Call accessible lines Call VL 13 Call VL 14 Call VL 15 Call VL 16 Wait 0 Tab
7 1. The PBX configuration instrument menu The basic menu for the PBX configuration instrument contains the following items: 1.1. Data New
70 Action Parameter Wait 4 DISA 1 Wait 6 DISA End Call VL 12 Call VL 13 Wait 20 Call operator Wait 30 Voice 3 Call voicemail
71 IMPORTANT!! When using the DISA services in the ringing table then the row Wait 0 is not allowed to occur ! 2.5.8. Global data see Global da
72 2.6. Saving automat activated. For lines that use the LC
73 2.6.2. Routes - providers Here routes are allocated that can be used by the external line bundles to make a connection. They are always selecte
74 telephony, we can determine that this Brno number uses, of instance, route 1, which also goes through a GSM module and totally replaces the numb
75 Example 3: Other authorisation. If an internal line was set to Obligatory use of LCR, then the numbers of frequently phoned business partners co
76 2.7.2. Switches, Broadcast, Tape Recorder Enter the port relay for Activate temporary/permanent switch for groups PBX 1 and 2. Temporar
77 2.7.3. Intercoms two intercoms for each group. Ring
78 In this menu it is possible to set two times for automatically switching to the DAY and NIGHT regimes for each group and for every day. Ticking
79 The voice at the start of redirecting is used at the start of being redirected to the VTS. The voice when exceeding the call period during redi
8 1.2. Windows Cscade Grouping the windows into a cascade Tile Grouping the windows next to each other without overlap Arrange icon
80 2.8. Switches Set the binary switch actions in this MENU section. You can create a table of actions for each binary switch and specify for eac
81 Caution: If already used as a Relay contact in the configuration (temporary/permanent switch, AUX relay), a switch cannot be
82 Turn to Day/Night turn the PBX into the DAY/NIGHT mode and vice versa. Switch on relay activate the selected relay. Swi
83
84 2.9. Numbering 2.9.1. Internal lines See Internal lines /Numbering 2.9.2. Services
85 2.10.2. External lines 2.10.2.1. Making accessible The table has as many columns as there are internal subscribers and as many rows as there a
86 2.11. Mobility Extension Mobility Extension function enables telephone stations (preferably GSM telephones to share internal line
87 A common quick dialling established in the Mobility Extension IN/OUT environment can only be edited here. Direct editing in the “Commo
88 2.11.2. Mobility Extension OUT Here you set up the conditions for Mobility Extension in the outgoing direction, the allocated internal line r
89 Answered call - Called party does not answer the call on any of his stations (ME or certain extension). SMS at No Answer The text is used f
9 1.4. Help Contents help for words in help Using help general instructions for using help in OS WIN About the appl
90 2.11.3. Mobility Extension services These services are executed based on a command from Mobility Extension. After detecting the DTMF character
91 2.12. Auto CLIP Routing CLIP Routing helps callers from the PSTN to call back the call-establishing subscriber line in the PBX, overriding t
92 Set the following: - Save latest records only -the CallBack database only includes the last (most recent) calls to the selected PSTN n
93 The ringing adding options can be combined. Add ringing to another subscriber line is applied first, followed by Add ringing table. 2.12.2. C
94 - Validity -define how long the record will be valid. - Line -specify the internal line that made the record (made an outgoing u
95 2.13. Short / Speed - Dialling 2.13.1. Common Abbreviated Dialling You can enter up to 200 common abbreviated dialling options into the PBX.
96 2.13.2. Private Abbreviated Dialling Key telephone users may enter additional 112 private dialling options that can be retrieved from the parti
97 2.14. Export/Import of Abbreviated Dialling It is possible to Import/Export the Abbreviated Dialling from/to a file. From an active window yo
98 -name of the file is automatically given (ShortCom) with a destination (folder, where OMEGA Lite Program is installed) - choose the type o
99 -name of the file is automatically given (ShortLxx) according to the extension number with a destination (folder, where OMEGA Lite Program is
Commenti su questo manuale